ADDITIONAL NEW TEST RESULTS FOR AKUSTIK + SYLOMER SUPPORTS IN A CROSS LAMINATED TIMBER (CLT) CONSTRUCTION

Additional New test results

Additional New test results

This article details the results of tests of a suspended ceiling and floating floor in a CLT construction.

4/3/2024

This article details the results of tests of a suspended ceiling and floating floor in a CLT construction. The objective of these tests was to determine the improvement of acoustic quality in the building construction. AMC Mecanocaucho, together with FCBA, is committed to offering precise and detailed results that help transform the way buildings are built. These tests complete the tests already shown in the following news:

LINK

INTRODUCTION

Cross Laminated Timber (CLT) framing is made of layers of wood boards that are glued together. The boards of each layer are oriented perpendicular to the adjacent layers, so similar structural properties can be obtained in both directions.

In general, wooden structures are more difficult to soundproof due to their relatively low mass compared to concrete structures, making the proper selection of sound insulation products critical.

TEST RESULTS

In order to show the acoustic advantages of using the Akustik Lateral + Sylomer® hangers and the Akustik + Sylomer® floor mounts, impact noise and airborne noise tests were completed on a Cross Laminated Timber structure.

The objective of this installation is to comply with the Acoustic regulations and the Acoustic quality classification for on-site tests.


Acoustic regulations Acoustic Quality Classification
Impact noise, L'nTw <58db Impact noise, L'nTw <55db
Airborne noise, DnT,w + C100-3150 >53db Impact noise, L'nTw + C1,50-2500 <55db

The results of the acoustic tests for each configuration are shown below:


G1 system


Scheme Impact noise results – L'nT (dB)
L'nTw: 86 dB IIC 24
Go to Impact Noise Results Report L'nT (PDF)
Description
  • 0. Without floor covering
  • 1. CLT 140mm
Impact noise results– L'i,Fmax,V,T (dB) Airborne noise results – Dnt (dB)
0
0
L'i,Fmax,V,T: 52 dB
IIC 58
DnT,w: 39 dB
STC 39
Go to Impact Noise Results Report L'i,Fmax,V,T (PDF) Go to Airborne Noise Results Report D’nt (PDF)

F1 system


Scheme Impact noise results – L'nT (dB)
L'nTw: 61 dB IIC 49
Go to Impact Noise Results Report L'nT (PDF)
Description
  • 0. Without floor covering
  • 1. CLT 140mm
  • 2. Hanger AKUSTIK+SYLOMER 15
  • 3. Profiles S47 17/6
  • 4. Glass wool 75 mm URSA PRK 35
  • 5. 1 TWIN FLAM BA18 panel
Impact noise results– L'i,Fmax,V,T (dB) Airborne noise results – Dnt (dB)
0
0
L'i,Fmax,V,T: 58 dB
IIC 52
DnT,w: 59 dB
STC 59
Go to Impact Noise Results Report L'i,Fmax,V,T (PDF) Go to Airborne Noise Results Report D’nt (PDF)

G2 system


Scheme Impact noise results – L'nT (dB)
L'nTw: 72 dB IIC 38
Go to Impact Noise Results Report L'nT (PDF)
Description
  • 1. PVC flooring
  • 2. CLT 140mm

F2 system


Scheme Impact noise results – L'nT (dB)
L'nTw: 54 dB IIC 56
Go to Impact Noise Results Report L'nT (PDF)
Description
  • 1. PVC flooring
  • 2. CLT 140mm
  • 3. Glass wool 75 mm URSA PRK 35
  • 4. Hanger AKUSTIK+SYLOMER 15
  • 5. Profiles S47 17/6
  • 6. 1 TWIN FLAM BA18 panel

G3 system


Scheme Impact noise results – L'nT (dB)
L'nTw: 73 dB IIC 37
Go to Impact Noise Results Report L'nT (PDF)
Description
  • 1. Cork base + laminated parquet 14mm
  • 2. CLT 140mm

F3 system


Scheme Impact noise results – L'nT (dB)
L'nTw: 53 dB IIC 57
Go to Impact Noise Results Report L'nT (PDF)
Description
  • 1. Cork base + laminated parquet 14mm
  • 2. CLT 140mm
  • 3. Glass wool 75 mm URSA PRK 35
  • 4. Hanger AKUSTIK+SYLOMER 15
  • 5. Profiles S47 17/6
  • 6. 1 TWIN FLAM BA18 panel

Do not hesitate to contact our application engineers for more information on this product.