This article details the results of tests of a suspended ceiling and floating floor in a CLT construction. The objective of these tests was to determine the improvement of acoustic quality in the building construction. AMC Mecanocaucho, together with FCBA, is committed to offering precise and detailed results that help transform the way buildings are built. These tests complete the tests already shown in the following news:
LINK
INTRODUCTION
Cross Laminated Timber (CLT) framing is made of layers of wood boards that are glued together. The boards of each layer are oriented perpendicular to the adjacent layers, so similar structural properties can be obtained in both directions.
In general, wooden structures are more difficult to soundproof due to their relatively low mass compared to concrete structures, making the proper selection of sound insulation products critical.
TEST RESULTS
In order to show the acoustic advantages of using the Akustik Lateral + Sylomer® hangers and the Akustik + Sylomer® floor mounts, impact noise and airborne noise tests were completed on a Cross Laminated Timber structure.
The objective of this installation is to comply with the Acoustic regulations and the Acoustic quality classification for on-site tests.
Acoustic regulations |
Acoustic Quality Classification |
Impact noise, L'nTw <58db |
Impact noise, L'nTw <55db |
Airborne noise, DnT,w + C100-3150 >53db |
Impact noise, L'nTw + C1,50-2500 <55db |
The results of the acoustic tests for each configuration are shown below:
G1 system
Scheme |
Impact noise results – L'nT (dB) |
|
|
L'nTw: 86 dB |
IIC 24 |
Go to Impact Noise Results Report L'nT (PDF)
|
Description |
- 0. Without floor covering
- 1. CLT 140mm
|
Impact noise results– L'i,Fmax,V,T (dB) |
Airborne noise results – Dnt (dB) |
|
|
L'i,Fmax,V,T: 52 dB |
IIC 58 |
DnT,w: 39 dB |
STC 39 |
Go to Impact Noise Results Report L'i,Fmax,V,T (PDF)
|
Go to Airborne Noise Results Report D’nt (PDF)
|
F1 system
Scheme |
Impact noise results – L'nT (dB) |
|
|
L'nTw: 61 dB |
IIC 49 |
Go to Impact Noise Results Report L'nT (PDF)
|
Description |
- 0. Without floor covering
- 1. CLT 140mm
- 2. Hanger AKUSTIK+SYLOMER 15
- 3. Profiles S47 17/6
- 4. Glass wool 75 mm URSA PRK 35
- 5. 1 TWIN FLAM BA18 panel
|
Impact noise results– L'i,Fmax,V,T (dB) |
Airborne noise results – Dnt (dB) |
|
|
L'i,Fmax,V,T: 58 dB |
IIC 52 |
DnT,w: 59 dB |
STC 59 |
Go to Impact Noise Results Report L'i,Fmax,V,T (PDF)
|
Go to Airborne Noise Results Report D’nt (PDF)
|
G2 system
F2 system
G3 system
F3 system
Do not hesitate to contact our application engineers for more information on this product.