TSR 150 x 150

Support 150×150 with leveling option and pads of 25 or 50 mm. Allows natural frequencies < 8 Hz and offers high isolation capacity.

The AMC-MECANOCAUCHO® TSR type anti vibration mounts include a microcellular and resilient polyurethane compound for anti-vibration purposes called Sylomer®. This Sylomer® is oil resistant and with a temperature range of -30°C/+70°C.

The TSR mounts can be fixed mechanically thanks to the internal nut incorporated to the metallic part that is treated with an antioxidant coat. This coating complies to the RoHs regulations.

In order to match the application, 6 different densities are supplied for a wide range of loads.

Alt imagen
TypeCodeMax.Load (kg)B(mm)H(mm)MWeight(kg)Min. Load (kg)Freq. (Hz) Min. LoadFreq. (Hz) Max. LoadBIM
TSR 150x150 SR_110 M16 + Kit Niv.15712023025108162.250-11,38
15717620250108161.950-8,11
TypeCodeMax.Load (kg)B(mm)H(mm)MWeight(kg)Min. Load (kg)Freq. (Hz) Min. LoadFreq. (Hz) Max. LoadBIM
TSR 150x150 SR_220 M16 + Kit Niv.15712143025108162.2523114,3610,53
15717737550108162.3720310,207,50
TypeCodeMax.Load (kg)B(mm)H(mm)MWeight(kg)Min. Load (kg)Freq. (Hz) Min. LoadFreq. (Hz) Max. LoadBIM
TSR 150x150 SR_450 M16 + Kit Niv.15712286025108162.2543114,089,97
15717870950108162.53237610,437,59
TypeCodeMax.Load (kg)B(mm)H(mm)MWeight(kg)Min. Load (kg)Freq. (Hz) Min. LoadFreq. (Hz) Max. LoadBIM
TSR 150x150 SR_850 M16 + Kit Niv.157123142025108162.2586114,5111,30
157179109350108162.727109,457,61
TypeCodeMax.Load (kg)B(mm)H(mm)MWeight(kg)Min. Load (kg)Freq. (Hz) Min. LoadFreq. (Hz) Max. LoadBIM
TSR 150x150 SR_1200 M16 + Kit Niv.157124190025108162.25142112,2710,61
157180141850108162.7410948,557,51
TypeCodeMax.Load (kg)B(mm)Weight(kg)Min. Load (kg)Freq. (Hz) Min. LoadFreq. (Hz) Max. LoadBIM
TSR 150x150 SR_110 M16157125230251.90-11,38
157145202501.90-8,11
TypeCodeMax.Load (kg)B(mm)Weight(kg)Min. Load (kg)Freq. (Hz) Min. LoadFreq. (Hz) Max. LoadBIM
TSR 150x150 SR_220 M16157126430251.923114,3610,53
157156375502.220310,207,50
TypeCodeMax.Load (kg)B(mm)Weight(kg)Min. Load (kg)Freq. (Hz) Min. LoadFreq. (Hz) Max. LoadBIM
TSR 150x150 SR_450 M16157127860251.943114,089,97
157154709502.2637610,437,59
TypeCodeMax.Load (kg)B(mm)Weight(kg)Min. Load (kg)Freq. (Hz) Min. LoadFreq. (Hz) Max. LoadBIM
TSR 150x150 SR_850 M161571281420251.986114,5111,30
1571551093502.47109,457,61
TypeCodeMax.Load (kg)B(mm)Weight(kg)Min. Load (kg)Freq. (Hz) Min. LoadFreq. (Hz) Max. LoadBIM
TSR 150x150 SR_1200 M161571291900251.9142112,2710,61
1571571418502.810948,557,51
Elastic properties
Advantages
01
Easy Installation
This mount requires minimal structural modifications, making installation quick and straightforward.
02
Improved isolation
It offers improved isolation compared with conventional anti-vibration mounts of similar geometry.
03
Incorporates Sylomer® elastomer, highly effective for isolating both high and low frequencies
Sylomer® provides high isolation across a wide frequency range and is particularly effective at high frequencies, effectively eliminating the transmission of structure-borne noise.