Acoustic isolation for timber and CLT buildings
High-performance acoustic isolation for mass timber construction

Transmission paths to be treated
In arder to properly isolate wooden structures from unwanted noise and vibration, the four transmission paths above must be considered:
Direct through the slab
From the wall through the slab
Straight through the wall
From the slab through the wall

NEW LABORATORY TEST RESULTS FOR THE AKUSTIK + SYLOMER FLOOR MOUNTS IN CROSS-LAMINATED TIMBER (CLT) STRUCTURES

NEW TEST RESULTS FOR THE AKUSTIK 1 + SYLOMER ACOUSTIC HANGERS IN A REAL INSTALLATION FOR A CROSS-LAMINATED TIMBER (CLT) STRUCTURE

CASE STUDY: FLOATING FLOOR WITH AKUSTIK + SYLOMER® FLOOR MOUNT IN CLT WOOD STRUCTURE.

LABORATORY TEST RESULTS FOR THE EP 700 + SYLOMER ACOUSTIC HANGER IN CLT STRUCTURES

NEW TEST RESULTS FOR AKUSTIK + SYLOMER SUPPORTS IN A CROSS LAMINATED TIMBER (CLT) CONSTRUCTION

ADDITIONAL NEW TEST RESULTS FOR AKUSTIK + SYLOMER SUPPORTS IN A CROSS LAMINATED TIMBER (CLT) CONSTRUCTION

NEW VIBRATION TEST RESULTS Dvij FOR STRUCTURAL NOISE INSULATION SYSTEMS IN A CROSS-LAMINATED TIMBER (CLT) CONSTRUCTION MODEL

NEW LAB TEST RESULTS FOR AKUSTIK LATERAL + SYLOMER HANGERS IN CLT CONSTRUCTION WITH A FLOATING SCREED WITH HEATING SYSTEM

AKUSTIK + SYLOMER FLOOR MOUNTS IN CLT STRUCTURES
This article shows the tests results for floating floor installations when used in Cross-Laminated Timber (CLT) structures, comparing them to the results of the bare CLT structure.

THE EP 700 + SYLOMER ACOUSTIC HANGER IN CLT STRUCTURES
This article shows the tests results for different Cross-Laminated Timber (CLT) structures when using acoustic hangers for the suspended ceiling.

INSTALLATION IN CROSS-LAMINATED TIMBER (CLT) STRUCTURE IN SCOTLAND
This article shows the tests results of a suspended ceiling for a real world installation when used in a Cross-Laminated Timber (CLT) structure.

CLT WOODEN STRUCTURE. EXTENSION OF THE TIANA MUSIC SCHOOL
In the extension of the public music school, they decided to use materials that were as sustainable as possible and respectful with the environment.

A CROSS LAMINATED TIMBER (CLT) CONSTRUCTION IN BURDEAUX, FRANCE
AMC Mecanocaucho, together with FCBA, is committed to offering precise and detailed results that help transform the way buildings are built.

VIBRATION TEST RESULTS Dvij FOR CROSS-LAMINATED TIMBER (CLT) IN BURDEAUX, FRANCE
AMC together with FCBA tested different configurations of walls and floors which included smart joints, aiming to decrease coupling at structural junctions.

AKUSTIK LATERAL + SYLOMER HANGERS IN CLT CONSTRUCTION WITH A FLOATING SCREED WITH HEATING SYSTEM
This article details the results of tests on a suspended ceiling and a floating screed with a heating system in a CLT construction.

CLT CONSTRUCTION
Demonstration videos comparing the audible noise in a hotel room, with CLT structure, which has a very noisy nightclub just above.

NEW AKUSTIK+SYLOMER® CLT WALL
Akustik amplia la sua gamma di supporti acustici a parete per costruzioni in legno con il nuovo supporto Akustik CLT Wall.

AMC-MECANOCAUCHO® updates the chapter for Noise and vibration isolation on wooden structure buildings on www.akustik.com

NEW LABORATORY TEST RESULTS FOR LIGHT WOOD STRUCTURES

NEW LABORATORY TEST RESULTS FOR THE AKUSTIK + SYLOMER MOUNTS IN DOWEL-LAMINATED TIMBER (DLT) STRUCTURES

REFURBISHMENT OF A RESIDENTIAL BUILDING IN GERMANY

NEW STUDY PRESENTED AT FORUM ACUSTICUM MALAGA 2025

SUSPENSION CEILING - LIGHT WOODEN STRUCTURE
We have carried out various tests in certified laboratories to demonstrate the benefits of using acoustic mounts. In these tests, we compare the results of rigidly installed ceilings against suspended ceilings with rubber and Sylomer mounts.

COMPARISON RIGID CEILING WITH SAND/ROCK WOOL VS ELASTIC
Comparative tables of German laboratory ift ROSENHEIM where noise impact and airborne noise of the wooden ceilings with sand and rock wool filling with and without AMC supports are compared.

EFFICIENCY OF THE AKUSTIK + SYLOMER LINES AT LOW FREQUENCIES
Andreas Rabold from IFT Rosenheim carried out an study called “Trittschalldämmung richtig bewerten” to evaluate the correlation between the value of Ln,w according to DIN EN ISO 717-2 and the subjective perception of impact noise on wooden ceilings.

LABORATORY TEST RESULTS FOR LIGHT WOOD STRUCTURES
In order to show the acoustic advantages when using Akustik+Sylomer® Floor mounts and Akustik + Sylomer® Super T60 acoustic hangers in a light wood construction, an independent external technological center has performed impact and airborne noise tests using different configurations in light wooden structures.

AKUSTIK + SYLOMER MOUNTS IN DOWEL-LAMINATED TIMBER (DLT) STRUCTURES
Different tests have been carried out using different solutions for the floating floor from a naked structure to an installation with several cement board layers with our floating mounts.

AKUSTIK + SYLOMER® CHANNEL CLIPS IN TIMBER JOISTS CEILING
This article shows the laboratory tests results for different suspended ceiling installations in timber joist ceiling structures.

REFURBISHMENT OF A RESIDENTIAL BUILDING IN GERMANY
The impact noise level requirement of 46dB was not being fulfilled with the existing installation.

TIMBER JOIST CONSTRUCTION
Demonstration videos comparing the audible noise in a hotel room, with Timber joist structure, which has a very noisy nightclub just above.

ADVANTAGES ON WOODEN STRUCTURES
Akustik+Sylomer® acoustic hangers provide an extraordinary performance on wooden structures.


NEW STUDY PRESENTED AT THE INTER-NOISE 2025 CONGRESS
Study on vibroacoustic characterization of a 3-storey CLT building using Kij indices and AMC decoupling systems